MR-only simulation Unleash the real power of MR simulation
This product is no longer available

Specifications

MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
Compatibility with MR-based auto-contouring
  • No
Density maps
  • Continuous Hounsfield Units
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
Compatibility with MR-based auto-contouring
  • Yes, for prostate and prostate OARs
Density maps
  • Discrete, five different classifications: water, fat, spongy bone, cortical bone, and air
MR-only simulation
MR-only simulation
Compatibility
  • Ingenia MR-RT 1.5T and 3.0T
Imaging protocol
  • Dedicated ExamCard provides sequences for:
  • 3D MRCAT source information (mDIXON)
  • Anatomical information for delineation (T2W TSE)
MRCAT generation
  • Running parallel to image acquisition on the MR console, embedded post-processing generates MRCAT images using:
  • Automated segmentation and tissue classification
  • Automated assignment of CT-based density values
Export to treatment planning systems
  • MRCAT images are DICOM conform (CT) for direct export to treatment planning systems
MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
See all specifications
MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
Compatibility with MR-based auto-contouring
  • No
Density maps
  • Continuous Hounsfield Units
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
Compatibility with MR-based auto-contouring
  • Yes, for prostate and prostate OARs
Density maps
  • Discrete, five different classifications: water, fat, spongy bone, cortical bone, and air
MR-only simulation
MR-only simulation
Compatibility
  • Ingenia MR-RT 1.5T and 3.0T
Imaging protocol
  • Dedicated ExamCard provides sequences for:
  • 3D MRCAT source information (mDIXON)
  • Anatomical information for delineation (T2W TSE)
MRCAT generation
  • Running parallel to image acquisition on the MR console, embedded post-processing generates MRCAT images using:
  • Automated segmentation and tissue classification
  • Automated assignment of CT-based density values
Export to treatment planning systems
  • MRCAT images are DICOM conform (CT) for direct export to treatment planning systems
  • 1. Accuracy means: MRCAT provides around 1 mm total geometric accuracy of image data in less than 20 cm Diameter Spherical Volume (DSV). MRCAT provides below 2 mm total geometric accuracy of image data in more than 40 cm Diameter Spherical Volume (DSV)*. * Limited to 32 cm in z-direction in more than 95% of the points within the volume
  • 2. Equivalent means: the simulated dose based on MRCAT images does not differ in 95% of the pelvic cancer patients (Gamma analysis criterion 3%/3mm realized in 99% of voxels within the PTV or exceeding 75% of the maximum dose) when compared with CT-based plan for EBRT.
  • 3. Tested in a non-clinical environment with single Pinnacle user and a 5-beam IMRT plan. Excluding time for optional manual adjustments.

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.

Vstopate na slovensko spletno stran Philips Healthcare
Please select the checkbox

Spletna stran je namenjena samo osebam, ki medicinske pripomočke uporabljajo kot profesionalci, vključno z osebami, ki opravljajo poklice v zdravstveni dejavnosti, osebami, ki delujejo za zdravstvene subjekte, ali subjekti, ki trgujejo z medicinskimi pripomočki kot profesionalci. Spletno mesto nikakor ni namenjeno potrošnikom ali splošni javnosti.

Ali ste oseba, ki izpolnjuje zgornja merila?

Da Ne